- –Pressure test the cooling system for leaks –Check thermostat operation –Check cooling fan/switch operation –Check drive belts and radiator hoses RESULTS OF LEAK IF ANY: UPPER RADIATOR HOSE RESULTS OF TEST: PASS ***CAUTION: YOUR VEHICLE MAY HAVE OVERHEATED AND HAVE ENGINE DAMAGE. IT IS DIFFICULT TO PROPERLY TEST FOR DAMAGE TO THE ENGINE UNTIL THE COOLING SYSTEM IS REPAIRED TO PROPER SPECIFICATIONS AND THE VEHICLE IS TESTED UNDER PROPER OPERATING CONDITIONS***
- REPLACE THE COOLANT RESERVOIR HOSE (LEAKING)
- CONDENSER – Remove & Replace – 2.4L Eng – [Includes: R&I Front Bumper Cover. DOES NOT include drain and refill Transmission Fluid or Fluid Level check.] – [DOES NOT include Air Conditioning System recover, evacuate and/or recharge.]
- EVAPORATOR EXPANSION VALVE – Remove & Replace – [DOES NOT include Air Conditioning System recover, evacuate and/or recharge.]
- — Identify refrigerant in use and check for contamination — Evacuate and charge A/C system with refrigerant — Add ultra-violet A/C dye to system — Examine exposed hoses, tubing and connections for damage/leaks — Examine compressor/clutch for damage/leaks** — Examine compressor for missing caps, proper labeling** — Rotate the compressor to determine if faulty — Examine the condensor coil for damage/restrictions/leaks — Examine the expansion device for damage or leaks** — Examine the accum./receiver/drier for damage or leaks — Check the drive belt system — Inspect fan clutch for leakage and bearing wear — Check fan clutch for proper operation — Inspect the cooling fan for bent or missing blades — Examine accessible electrical connections — Check system for leakage at a minimum of 50 psi — Check operation of the compressor clutch — Check operation of blower motor and air control doors ** If accessible LEAKS DETECTED: NONE AFTER REPAIRS PARTS DEFECTIVE: NONE AFTER REPAIRS Final high side operating pressure reading: 150 PSI Final low side operating pressure reading: 30 PSI Final center air distribution outlet temperature: 43 DEGREES F
CHRIS P. gave our service a 5 star review on 10/23/2024